Item CodeGFIS-RTD-200SKURTD10CS
Brand Raychem® Alternate Part Number 17066233 Country USA|Canada Manufacturer Chemelex Model RTD Temperature Rating -20 to 60 deg C Accuracy +/-1 deg F Application For temperature measurement up to 400 deg F, used with monitoring and control systems such as Raychem 910 controller when accurate temperature control is required, non-hazardous and CID2 locations Country of Origin US Measuring Range -76 to 400 deg F Resistance 100 Ohm
- The Raychem RTD-3CS and RTD-10CS are three-wire platinum RTDs (resistance temperature detector) typically used with monitoring and control systems such as Raychem 910 controller when accurate temperature control is required. Used in non-hazardous and CID2 locations. The RTD-3CS and the RTD-10CS can be installed directly to the controller using the supplied 1/2 in conduit fitting or to an RTD junction box where RTD extension wire is used.
- 1-1/2 in sensing area
- 20 AWG stranded tinned copper extension wire
- 300 V wire insulation rating
- AT-180 aluminum tape
- 3/16 in diameter and 3 in sensor length
- Simple and fast to install
- Direct connection to controller with 1/2 in/12.7 mm NPT fitting that connects to the conduit box-allows mounting of the RTD in a typical ambient and splicing of RTD extension wire back to the controller
- Sensor housing is 316 stainless steel, lead wire is heathed in Alloy 825
- Reliable during long life
$235.72
/ EAIn Stock
Request a quote for more detailed pricing including freight and taxes.
Brand Raychem® Alternate Part Number 17066233 Country USA|Canada Manufacturer Chemelex Model RTD Temperature Rating -20 to 60 deg C Accuracy +/-1 deg F Application For temperature measurement up to 400 deg F, used with monitoring and control systems such as Raychem 910 controller when accurate temperature control is required, non-hazardous and CID2 locations Country of Origin US Measuring Range -76 to 400 deg F Resistance 100 Ohm
- The Raychem RTD-3CS and RTD-10CS are three-wire platinum RTDs (resistance temperature detector) typically used with monitoring and control systems such as Raychem 910 controller when accurate temperature control is required. Used in non-hazardous and CID2 locations. The RTD-3CS and the RTD-10CS can be installed directly to the controller using the supplied 1/2 in conduit fitting or to an RTD junction box where RTD extension wire is used.
- 1-1/2 in sensing area
- 20 AWG stranded tinned copper extension wire
- 300 V wire insulation rating
- AT-180 aluminum tape
- 3/16 in diameter and 3 in sensor length
- Simple and fast to install
- Direct connection to controller with 1/2 in/12.7 mm NPT fitting that connects to the conduit box-allows mounting of the RTD in a typical ambient and splicing of RTD extension wire back to the controller
- Sensor housing is 316 stainless steel, lead wire is heathed in Alloy 825
- Reliable during long life